Is it doing that on all the bands or just some of them? It could be bad
soldering on the VCO board. My Paragon only does it on 160 and 75 meters, I
just have to re-flow the solder for that VCO, a lot of delicate work.
Steve w7jsc
Get Outlook for Android<https://aka.ms/ghei36>
________________________________
From: TenTec <tentec-bounces@contesting.com> on behalf of Ken Brown
<kenradiobrown@gmail.com>
Sent: Tuesday, September 5, 2017 11:45:38 AM
To: Discussion of Ten-Tec Equipment
Subject: Re: [TenTec] Tentec 585.
Start by opening it up and applying DeOxit to every connector. Unplug,
apply DeOxit, replug. Be careful there my be some connectors that can be
plugged back in offset by one or more pins, incorrectly.
DE N6KB
On Tue, Sep 5, 2017 at 3:57 AM, Robin Lentz <robinlentz1@hotmail.com> wrote:
> Good morning. I have a Tentec 585 which I have enjoyed using for years.
> In recent times it has developed a problem with the phase lock loop not
> wanting to lock. At first I could leave the rig on for a few minutes and
> pll would lock. Now I can run the rig all day and pll will not lock most
> of the time. Any suggestions on how to cure this problem? Thanks and 73
> de WA4NLF
> _______________________________________________
> TenTec mailing list
> TenTec@contesting.com
> http://lists.contesting.com/mailman/listinfo/tentec
>
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
|