Those two bands may share the same bandpass filters. I don't know off the
top of my head. If they do, I would check to see if the band select control
logic is getting to the bandpass filter board(s), Whether the control
voltages look the same on that line as on other band selection lines when
they are selected, and if the control voltages look good, then you will
need to see if there is something wrong with the relays, switching diodes
or the filters themselves. Could be as simple as a connector contact that
needs to be cleaned.
DE N6KB
On Sat, Aug 12, 2017 at 12:22 PM, Ron Notarius W3WN <wn3vaw@verizon.net>
wrote:
> It's always something...
>
> Just discovered (and I mean just) that I've lost both 20 and 17 meters on
> my
> Omni VI+. No receive, no transmit. But only on those two bands.
>
> No issues at all on the other bands. Obviously something common to both 20
> & 17 decided to let the smoke out.
>
> Any suggestions on what to look for?
>
> 73, ron w3wn
>
>
>
>
> ---
> This email has been checked for viruses by Avast antivirus software.
> https://www.avast.com/antivirus
> _______________________________________________
> TenTec mailing list
> TenTec@contesting.com
> http://lists.contesting.com/mailman/listinfo/tentec
>
_______________________________________________
TenTec mailing list
TenTec@contesting.com