Yes, exactly my problem Perry. Where are the reed switches located, on the
bandpass filter board?
3923.5 KHz 100+ watts Ic 14
7200 KHz 20 watts Ic 19
10100KHz 30 watts Ic 19
14300 KHz 9 watts Ic 19
18150 KHz 2 watts Ic 19
21300KHz 0 watts Ic 15
24950 Khz 2 watts Ic 11
28500 Khz 10 watts Ic 13
Steve w7jsc
-----Original Message-----
From: TenTec [mailto:tentec-bounces@contesting.com] On Behalf Of w8au@sssnet.com
Sent: Monday, March 27, 2017 9:58 PM
To: Discussion of Ten-Tec Equipment<tentec@contesting.com>
Subject: Re: [TenTec] Paragon low power Output
At 10:58 PM 3/27/2017, you wrote:
My Paragon puts out full power on 80 meters, but has low power output
on all the other bands. Is there a Paragon expert out there that can
point me in the right direction on troubleshooting this problem? I'm
using a 50 ohm dummy load of course. It had full output on all bands
until one day I turned it on and I couldn't get full power. The amps
(Ip) look about where it should be, but output is way down.
Check your collector current on the bands with low output. Is it the same
as the 80 meter reading with full output? If so.....
Check your TX output bandpass filter reed switches. Check to see if the reed
switches are off on the bands not being used.
Typically this problem is caused by reed switches not being turned off or just
stuck on when not using those bands, causing a heavy load on the final and low
output.
Perry w8au