Hi Stan,
Replace both 20M relays on the low pass filter board. 99.9% chance that'll fix
it.
Later, Joe, K8MP
Sent from AOL Mobile Mail
-----Original Message-----
From: Stan Lloyd <kd8ln.stan@gmail.com>
To: tentec <tentec@contesting.com>
Sent: Sun, Feb 19, 2017 09:50 PM
Subject: [TenTec] Omni VI+ no output on 20 m
Hi,
I have an Omni VI+ that has stopped putting out any power on 20m in any mode.
It switched into transmit mode, and in CW It generates the side tone, but based
on the internal meter and an external power meter it gives absolutely zero
power output. It transmits fine with regular output on the other bands. Any
ideas on how to approach this?
I did try resetting the microprocessor, but no change.
Thanks and 73,
Stan KD8LN