This is a common problem with Paragons. The fix is to remove the PLL
board and reflow all the solder joints on that board. The problem is
cold solder joints that don't show up until much later in the radio's life.
Carl Moreschi N4PY
58 Hogwood Rd
Louisburg, NC 27549
www.n4py.com
On 8/26/2016 3:01 PM, k7mks@comcast.net wrote:
In past 2 days my Paragon, after having been turned OFF for several hours up to
overnight, has experienced 2 failures of PLL locking. In each instance, after
turning on the Paragon, i pressed the RESET button and normal operation for
hours, in all respects (mode and band changes) plus power output, was returned
This is a cosmetically excellent radioi with all fllters and a Giehl chip The
"P" word has not entered the picture yet but my comfort zone with PLL's is
zero. Would appreciate helpful comments to help keep this radio in one piece!
Thank you Joe k7mks
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
|