I recently acquired an early Centurion (serial 10A10221) from an SK's
estate. The resting plate current, PTT not keyed, is around 100 ma and
the 3-500ZGs have a nice orange plate glow. I had read in the archives
that later changes resulted in a much lower resting plate current and
set out to see what the current state of circuits is in this amp. ( Yes,
I know that level of plate current is OK, but it generates considerable
heat on the desk that I don't need.)
The amp has obviously been updated at some point as the Filament-AC
board has the new bias circuitry and the QSK board is revision C. The
Filament-AC board circuit as shown in the 10/94 rev C diagram agrees
with the schematic. So, I'm guessing that I might have all the latest
changes in regards to bias. The question is: Is the observed 100 ma
resting plate current what others are seeing in the Centurion with the
later bias changes? If that level is normal, I was thinking about maybe
using the Ameritron ESB-1H board which would reduce the resting current
to just about nothing with no excitation. Any thoughts? Tentec has not
responded to an email on the subject.
73, Floyd - K8AC
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
|