TenTec
[Top] [All Lists]

[TenTec] Delta II intermittent RX (VCO issue?)

To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
Subject: [TenTec] Delta II intermittent RX (VCO issue?)
From: "Mark Kenward" <k8vf_mark@centurytel.net>
Reply-to: Mark Kenward <k8vf_mark@centurytel.net>, Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Sat, 12 Dec 2015 21:50:56 -0500
List-post: <tentec@contesting.com">mailto:tentec@contesting.com>
Before you do anything else, check solder joints in vco 3 area on VCO 
board.....you will surely see some bad joints, or contaminated joints.  Re 
solder anything in that are looking dull, or contaminated(wick off the ugly 
stuff first)

Paragon II I got had this problem and was easily repaired once board was 
pulled...

If it isn't too much trouble, just remove and re solder whole board.

Just my 2 cents, from having same issue.


K8VF
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec

<Prev in Thread] Current Thread [Next in Thread>