To: | Discussion of Ten-Tec Equipment <tentec@contesting.com> |
---|---|
Subject: | Re: [TenTec] Orion S-meter calibration |
From: | KA9EGW <ka9egw@ka9egw.com> |
Reply-to: | Discussion of Ten-Tec Equipment <tentec@contesting.com> |
Date: | Tue, 26 May 2015 09:28:40 -0500 |
List-post: | <tentec@contesting.com">mailto:tentec@contesting.com> |
-73 dBm is 50 uV which is one accepted standard for S9. Seems like your s meter is linear in that part of the range, just very generous (by 20dB)...not to show my admitted ignorance, but does that rig have a built-in, switchable, 20dB preamp? 73, Brian KA9EGW _______________________________________________ TenTec mailing list TenTec@contesting.com http://lists.contesting.com/mailman/listinfo/tentec |