I should have mentioned I'm well aware of the procedure shown at
http://www.tentecwiki.org/lib/exe/fetch.php?media=s-meter_565.pdf   - I am
suggesting that this procedure is incomplete.  When I set the meter to read
100W when transmitting 100W and then follow that procedure, I end up
reading s5 on a 50uV s9 signal.

There was a thread 3 years ago at
http://lists.contesting.com/_tentec/2012-01/msg00014.html  that is speaking
of this matter but I don't understand the method alluded to so was asking
if anybody know.

Barry N1EU

On Fri, Jan 9, 2015 at 9:46 PM, Barry N1EU <barry.n1eu@gmail.com> wrote:

> Could someone please tell me how I adjust the s-meter calibration numbers
> in the hidden menu (RX Menu, then push PWR) such that an s9 signal
> registers s9, etc?
>
> I first set the meter pot (access hole in top panel behind AUDIO button)
> so that meter registers 100W when transmitting 100W.  Now I want to adjust
> s-meter but I'm confused on adjusting those numbers.
>
> Thanks & 73,
> Barry N1EU
>