The Corsair uses two signal lines to know whether to be in Receive or
Transmit.
They are called "R" and "T".
They are about +8v when active and 0v when inactive.

Only one can be active at a time.

The signal/voltages are available on nearly every board.
You need to locate them, preferably on the control board and check to see if
they are working correctly.

73 - Rick, DJ0IP
(Nr. Frankfurt am Main)


-----Original Message-----
From: TenTec [mailto:tentec-bounces@contesting.com] On Behalf Of gary
mankoff
Sent: Wednesday, December 24, 2014 4:09 PM
To: tentec@contesting.com
Subject: [TenTec] CORSAIR NO RX OR TX

CORSAIR LIGHTS UP ...
NO TX OR RX ...
WHERE SHOULD I LOOK ...
73...