The PIV rating on the original component is marginal.
73
Bob, K4TAX
----- Original Message -----
From: "Ken Brown" <ken.d.brown@hawaiiantel.net>
To: <tentec@contesting.com>
Sent: Sunday, September 21, 2014 1:44 PM
Subject: Re: [TenTec] 961 PS REPAIR / REPLACEMENT---WTB 961PS
Diodes don't usually fail without a reason. The reason is often a
failure of some other part. Yes it would definitely be wise to check around.
When my 961 bridge rectifier failed I replaced it with a KBPC3510 - a drop
in replacement rated at 1000v 35A. New cost here in UK is £2.40.
No other components had failed on mine, but it would be wise to check
around.
DE N6KB
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
|