All makes sense.

I don't suggest running the ground under the structure. I used some 3/8" soft copper water line for mine. In my case it is about 70 ft around the perimeter between the tower ground and the mains ground. Stuff is expensive but cheaper than #2 copper.

Put a driven ground just outside where the lines enter/exit the structure. Lightning protection is applied there. The key point that most miss, just be sure all grounds are tied together outside of the structure.

A 20 amp 120V ckt is nice but I would have preferred to run a 230V just in case I needed more juice. Even with the 230 V you can split that off to two 120 V circuits with common neutral and common ground.

73
Bob, K4TAX






----- Original Message ----- From: "denton sprague" <denton@oregontrail.net>
To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
Sent: Wednesday, May 14, 2014 8:20 PM
Subject: Re: [TenTec] Eagle problem?


Nice going Bob…as you might recall, I put out a query on qrz and a couple of other places about the xyl and I having a new double wide installed on our qth….and me running twin lead underneath the floor and out the back for a multi band horizontal loop…we will be having a concrete pad with presumably contruction cloth for reinforcement poured. That got shot down pretty nicely, so will go to plan B…making a porthole in the side of the new house for balanced feeders plus a couple of coaxial lines for other stuff…and installing a ground rod via ICE type glitch arrestors and static drains. Trouble is…the station is on the north side of the house and the electrical panel with attendant ground rod will be on the south side of the house. NEC says run a really thick cable and a bunch of ground rods around the perimeter of the house to connect the station ground to electrical ground. Question..can I run the ground line from the twin lead ground rod to the electrical input ground rod underneath the house? I will be making provisions to have the contractor install portholes in the foundation perimeter to run coaxial feed lines from the station room's porthole to the back of the new house.
From what I have seen…no can do….gotta run around the perimeter of the
house.
Antenna is a multi band horizonal loop up about 30 feet, fed with an LL (balanced Pi) tuner fer 10 thru 160 meters with an ICE type glitch arrester and 450 ohm (?) modified twin lead.
when I was kid I had a crystal radio….I think I miss it a lot….
BTW…I did have the forethought to have the construction people run a dedicated 20 amp 120 vac line just for the station.
If this don't make much sense, blame the nice whiskey I am imbibing!
On May 14, 2014, at 4:38 PM, "Bob McGraw - K4TAX" <RMcGraw@Blomand.net> wrote:

Why? I bring mine all the way to the tuner sitting on the shelf above the radio. If the line is operating anywhere near a balanced condition there will be little to no radiation from the feed line.

Ground? Someone said use one for lightning protection. Why? All lightning protection should be OUTSIDE of the house and never inside. I operate from the 2nd floor of the house. No ground from the station to the outside is ever needed.

I still question why connect the data audio into the mike input. The signal to the radio from the computer needs to be 20 to 30 db higher which will improve the signal to noise ratio. Thus the level of RF will be effectively reduced 20 to 30 db. There is no magic here, just math.

Yes, one can change the feedline length which will move the voltage point, perhaps further from the radio. Still, that is not perceived to be the best solution.


73
Bob, K4TAX





----- Original Message ----- From: "Mike Schatzberg" <cherokeehillfarm@earthlink.net>
To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
Sent: Wednesday, May 14, 2014 6:16 PM
Subject: Re: [TenTec] Eagle problem?


Hello Carter,

Why not eliminate the balanced line near the house?

Install a 4:1 current balun on the balanced line well away from the house, and connect from the balun to your tuner with 50 ohm coax. Bring it thru the wall and have nothing radiating in the shack.

A line isolator can also be installed right before the Eagle.

I sit under a fan dipole and have no issues with 100 watts portable.

Naturally, a good single point ground with a short low impedance ground connection is desirable, but I operate at the beach from the second floor without it.

Leave the RF outside.

73,

Mike
W2AJI

Sent from my iPhone

On May 14, 2014, at 6:43 PM, "Rick - DJ0IP / NJ0IP" <Rick@DJ0IP.de> wrote:

Actually James hit on an important point here:  feedline length.

Actually it has nothing to do with impedance matching but everything to do
with the behavior of common mode current on the feedline.
Unlike the transmitted RF current which is the same for the entirelength of the feedline, common mode current is not the same at all places along the
feedline.  It varies constantly.
It is worst a half wavelength away from the feedpoint and minimum a quarter
wavelength away from the feedpoint.
You must consider the vf of the feedline (but not its transmission line vf,
rather the vf of the individual wires - which is probably about .97 our
.98).

G3TXQ reports measured data on this on his web site at the bottom of his
page on RF chokes:
http://www.karinya.net/g3txq/chokes/

You didn't specify which band(s) the problem is on.
A quick try would be to insert 1/8 wavelength of additional feedline between
the existing feedline and the JV Matchbox.
Of course it you are on 80m, this is not going to be an option.

I still suggest the dual RF choke as per my previous email.

73 - Rick, DJ0IP
(Nr. Frankfurt am Main)


-----Original Message-----
From: TenTec [mailto:tentec-bounces@contesting.com] On Behalf Of TTMaven

Have you tried different lengths of feed line - window line and coax,
respectively? I won't recite all the reasons here, but you know how various
lengths of feed line matter to impedance matching, etc.

_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec


_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec


_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec


_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec

<Prev in Thread] Current Thread [Next in Thread>