Cecil:

I don't have a problem with your concept as long as the outside work is done first and correct. That says the outside system must be bonded to the AC mains.

Failure to do this will then tie the outside system to the equipment inside which is connected to the AC mains. Thus the path of destruction is through the radio equipment, regardless if it is ON or OFF, antenna connected or disconnected.

73
Bob, K4TAX






----- Original Message ----- From: "Cecil" <chacuff@cableone.net>
To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
Sent: Wednesday, May 14, 2014 7:20 PM
Subject: Re: [TenTec] Lightning protection




Sent from my iPad

On May 14, 2014, at 6:38 PM, "Bob McGraw - K4TAX" <RMcGraw@Blomand.net> wrote:

Ground? Someone said use one for lightning protection. Why? All lightning protection should be OUTSIDE of the house and never inside. I operate from the 2nd floor of the house. No ground from the station to the outside is ever.

73
Bob, K4TAX

I like you Bob......

But we will never agree on that one....

Too many documents and industry standards say and do otherwise....

First line of defense is definitely outside but not continuing that protection to a shack central point ground system with all equipment bonded too it and the building electrical safety ground system is only doing half the job...

It's the system design used in every Cellular/PCS/SCADA/Public Safety radio system out there....systems that have to run 24/7 lightning or not, all usually with 200'+ tower heights.

I'm sure Jim will hammer me next.....

Sorry guys...it's my training and vocation...building and maintaining these systems....why wouldn't one carry that philosophy as much as is practical into our stations...I have with excellent results. My tower gets popped a couple times a year and no damage to anything.

Of course this has nothing to do with the Eagle RFI problem...but I felt compelled to comment. (Changed the title so as to not hijack the thread)

Dead horse ....I know...

Cecil
K5DL

TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec



_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec

<Prev in Thread] Current Thread [Next in Thread>