Bob and the gang

When the new parts come in I plan on changing out the reset cap since the pcb 
will be pulled.  I mean why not? 

Mike wb8vge

Sent from my iPhone

On Aug 22, 2013, at 5:37 PM, "Bob McGraw - K4TAX" <RMcGraw@Blomand.net> wrote:

> As a general rule, electrolytic caps decrease in value as they age.  That 
> being the case here, the value could now be 1/4 of its original value and 
> which makes the simple RC timing just too fast for the system to load and 
> boot.  A  new cap or one that's 50% larger might just solve the problem.
> 
> 73
> Bob, K4TAX
> 
> 
> 
> 
> ----- 
> 