TenTec
[Top] [All Lists]

[TenTec] UPDATE - 9420 PS Problem

To: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Subject: [TenTec] UPDATE - 9420 PS Problem
From: Rick W <ve7tk@yahoo.ca>
Reply-to: Rick W <ve7tk@yahoo.ca>, Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Tue, 11 Jun 2013 17:13:42 -0700 (PDT)
List-post: <tentec@contesting.com">mailto:tentec@contesting.com>
The replacement 9420 Power Supply Controller transformer (T5) arrived from 
Digi-Key this morning and I have good news and .... more good news!  

After installation the Hercules II is back in business BUT even more surprising 
the replacement transformer mounted in the original holes!  So no drilling was 
needed.

I finally settled on the following laminated, chassis mount transformer:
Manufacturer:  TRIAD
Model: VPS16-2700
Output: 8 VAC at 5.4 amps or 16 VAC at up to 2.7 amps
Digi-Key Part:  237-1261-NDThis is a dual primary (pair of 115 VAC 
primaries) with a pair of 8 VAC secondaries.  I wired the secondaries in series 
to provide up to 2.7 A at 16 VAC.

Total cost delivered was just over $21 CAN. 

Needless to say, I'm a happy camper!

73,
Rick
VE7TK

Website: http://www.ve7tk.com