On 5/16/2012 12:22 PM, Stuart Rohre wrote:
> Likely with a second floor shack, ONLY the tuned ground lead would help your 
> RFI.

Repeat after me:

A CONNECTION TO EARTH HAS NOTHING TO DO WITH RFI.

A CONNECTION TO EARTH HAS NOTHING TO DO WITH RFI.

A CONNECTION TO EARTH HAS NOTHING TO DO WITH RFI.

A CONNECTION TO EARTH HAS NOTHING TO DO WITH RFI.

A CONNECTION TO EARTH HAS NOTHING TO DO WITH RFI.

A CONNECTION TO EARTH HAS NOTHING TO DO WITH RFI.

A CONNECTION TO EARTH HAS NOTHING TO DO WITH RFI.

A CONNECTION TO EARTH HAS NOTHING TO DO WITH RFI.

A CONNECTION TO EARTH HAS NOTHING TO DO WITH RFI.

What matters is proper bonding of cable shields to the chassis of the 
equipment to which it is connected, and the proper bonding of every 
equipment chassis to each other.

73, Jim K9YC