Casey,
I will take as stab at it, but don't have my schematic at hand.  The 
gradual rise and falling back seems like a capacitor charging.  The 
twitch could be a leaking capacitor.  The reversed deflection could be a 
capacitor shorted and thus allowing an incorrect voltage polarity.  It 
could also be a diode problem.  Open or short, I would have to refer to 
a schematic.
But anyway, I doubt if it is the meter itself; it is the rectifying and 
filtering circuit board that processes the signals to the meter, power 
and RF.  Check the SWR detector diodes and associated circuits, and the 
power circuits.  After checking the obvious things, and you don't figure 
it out call Ten Tec Service, likely they have seen the symptoms before.
Good Luck,
Stuart Rohre