Over the weekend my 962 supply for my Omni VI blew the ac fuse every
time I turned it on. I expected that the bridge rectifier could be the
problem. When I opened it up, I found that the bolt holding down the
filter board was loose leaving the bridge without a heat sink. I
haven't unsoldered the bridge but expect that it's the likely
problem. Has anyone else experienced blown fuse problems with the 962?
Also, is this a part I can but from Ten-Tec without buying an entire
board? If not, does anyone know the specs for a direct replacement?
Since it's a holiday weekend, there's no chance to call Ten-Tec until
Tuesday.
For me, if anything every breaks around the house, it's on a holiday.
I've had furnaces go out, dishwashers, stoves and any other number of
appliances go out on Christmas, July 4 or Memorial Day. This must be
my 2009 holiday breakdown.
Thanks for any input.
Phil N3ZP