Hi Jeff,
>  The day the internal meter started showing me 60 watts is the same time the 
> external meters started showing me 125 watts, The rig use to show around 98 
> watts all the time. Any idea whatʼs up?
>   
Are you sure the load has not changed? Different power readings from 
meters at different distances from the load is a clue that there may be 
standing waves. Do you get the same indications using a reliable 50 ohm 
non-inductive termination. Make sure all of the cables you are using are 
still good, and check it out with a quality termination.

DE N6KB