The spark plug arrester has the disadvantage of rather blunt points.   Much 
better, as someone mentioned, is a pair of copper (prefereably) or brass 
plates with facing sharp points, gapped about l/32" (a little less than l 
mm.)  The suggested 90 degree angle is fine.   This will drain a static 
charge and carry quite a bit of current;  a resistor across the line will 
drain the static, but if there's enough charge to pruduce appreciable 
current the resistor won't last long.  -  -  The heavy knife switch to 
ground along with actual disconnecting the lead-in's from the equipment is 
obviously the best protection.  K3TX
----- Original Message ----- 
From: "Bob McGraw - K4TAX" <RMcGraw@Blomand.net>
To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
Sent: Monday, April 14, 2008 10:55 AM
Subject: Re: [TenTec] Ten Tec 238A settings?


> Yes, but with a knife switch one can't operate and be protected at the 
> same
> time.  With the spark plug arrestor operation continues with protection.
> The knife switch is best when one is away from the station.  That presumes
> one does not forget to close it when securing the station.  Also, the 
> knife
> switch should be located outside of the structure for added safety.
>
> 73
> Bob, K4TAX
>
>
> ----- Original Message ----- 
> From: "Lyle Dunlap" <qskqrq@grics.net>
> To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
> Sent: Monday, April 14, 2008 7:15 AM
> Subject: Re: [TenTec] Ten Tec 238A settings?
>
>
>> One can use all sorts of spark plugs & things to drain off those little
>> sparkies mother nature puts out, however its hard to beat a DPDT heavy
>> knife
>> switch.
>> For over 25 years I had a 3 wire Rhombic up 375 ft on a leg and with 4500
>> feet of wire basically in the form of a capacitor you can have your own
>> fireworks display.  Go with a knife switch.
>>
>> Lyle W9FCX
>>
>> _______________________________________________
>> TenTec mailing list
>> TenTec@contesting.com
>> http://lists.contesting.com/mailman/listinfo/tentec
>>
>
>
> _______________________________________________
> TenTec mailing list
> TenTec@contesting.com
> http://lists.contesting.com/mailman/listinfo/tentec 

_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec

<Prev in Thread] Current Thread [Next in Thread>