Hello Alan & all,

I just got a message from the Ten-Tec support and they'll send me 2 new 
capacities to replace C6 & C7 on the power distribution board (A9). It 
seems that the problem with these capacities is recurrent and affects 
many Orion's user...

73, Cedric HB9HFN

Date: 05.02.2008 15:37, Alan Sewell wrote :
> Sounds like it could be the power distribution board.  See this thread.
>
> http://lists.contesting.com/_tentec/2007-11/msg00073.html
>
> 73,
>
> Alan  N5NA
>
> http://www.tentecwiki.org
>
>
>
> Cedric Baechler wrote:
>   
>> Hello,
>> I have the following problem with my Orion II:
>>
>> When I start it by using the switch on/off button the Ten-Tec logo 
>> appears, then the normal screen (with frequency, sweep, ..) for a few 
>> seconds then it reboots itself. This can happen 5-6 times until the 
>> normal screen stays and the Orion is ready to use. Sometime during the 
>> boot process and when the normal screen appears I see a single 
>> horizontal white line on the screen!!
>>
>> Before I contact Ten-Tec, has someone had this problem previously and 
>> can help me?
>>
>> 73, Cedric HB9HFN
>>     