TenTec
[Top] [All Lists]

Re: [TenTec] Orion II back home

To: "TenTec List" <TenTec@contesting.com>
Subject: Re: [TenTec] Orion II back home
From: "Rick Williams" <rick.williams@telus.net>
Reply-to: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Thu, 30 Aug 2007 16:16:42 -0700
List-post: <mailto:tentec@contesting.com>
Well done Ron and here's a little more irony.

I received my Newark capacitors today.  Total time to remove the Orion from
the rack, undo all the torx screws remove and replace the caps (C6, C7 and
C9 from the power distribution board) and put it all back together was less
than an hour.

The original caps were:

       470 uF, 16 V, 85 C from CKRM

Replaced with:

      470 uF, 35 V, 105 C, Low ESR from Vishay (Newark part number 18C4716)

There was no problem installing these - lots of room - and the lead spacing
was perfect. Preventative maintenance done!

73, 

Rick 
VE7TK

Website:  http://www3.telus.net/ve7tk  

---------
 
Subject:        [TenTec] Orion II back home
From:   "Ron Castro"
Date:   Thu, 30 Aug 2007 15:03:05 -0700

I just got word from the XYL that my repaired Orion II was just delivered to

the house.  Ironically, my ACOM 2000A amplifier which had been sent back to
MA 
for a low voltage reading problem, arrived on the same truck!  

I'll be QRV for the 3-day weekend....

         Ron  N6IE
      www.N6IE.com

_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec

<Prev in Thread] Current Thread [Next in Thread>