TenTec
[Top] [All Lists]

Re: [TenTec] Circuit breaker tripping excessively DIAGNOSED

To: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Subject: Re: [TenTec] Circuit breaker tripping excessively DIAGNOSED
From: Craig Roberts <crgrbrts@verizon.net>
Reply-to: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Fri, 08 Dec 2006 11:59:37 -0500
List-post: <mailto:tentec@contesting.com>
I've found a culprit in my battle with the trigger-happy circuit breaker.

To recap:  The magnetic circuit breaker in my Model 225 power supply 
trips just as my Argosy II's output reaches the ALC activation point.  I 
was able to eliminate the symptom by adjusting the SWR bridge (on the 
Low Pass Filter board) so that it was off the null point in REV mode.  
Since ALC voltage is derived from the same circuit that drives the 
meter, this pointed to an ALC problem.  Sure enough, one of the pair of 
diodes that rectifies the the ALC voltage was open.  Replacing it should 
solve the problem (at least I hope so).  An order has been placd with 
Mouser and I'll let you know how the repair goes next week. We wonder, 
of course, why the diode blew.

Thanks to all who have offered advice and counsel.

73,

Craig
W3CRR

>  
>

_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec