Steve,
Many thanks for your help... My comments are appended to yours:
On 18/06/2006 at 13:03 n8kom@wowway.com wrote:
>Hi Bob,
>
>For CAT interface - serial communications between the Argo V and the PC - it
>is simply a 9-pin RS-232 cable, the same used for most all RS-232 serial
>computer devices. - No special cable or box is needed.
There are two 9-pin configurations possible:
a) TxD-TxD and RxD-RxD (pins 2-2 and 3-3)
b) TxD-RxD and RxD-TxD (pins 2-3 and 3-2), the null-modem setup
additionally there is loopback handshaking, RTS connected to CTS. I know that
the Argo V doesn't have handshaking, but unless RTS and CTS are high, the COM
port won't send. In MixW, I can set RTS and CTS as always on, which should do
the trick.
I still don't know which of (a) or (b) is correct for the Argo V. I would
normally expect (b) because the communication is two-way. However, my K2 uses
configuration (a), which Elecraft say is special for the K2. I've interfaced
other rigs and they used configuration (b).
>MixW (I think) allows the ArgoV to be selected from the setup menu for CAT
>control of frequency, mode, and PTT.
It does. PTT can be switched via the RTS line or via software. Via software
saves a wire.
>The audio interface cable (that Ten Tec sells for the Argo V) is simply a 5
>pin DIN connector that breaks out to RCA jacks for the audio in, audio out,
>and PTT.
Yes, I've done that already and it works fine. Audio out is 1 volt(!) so I've
put a pot. in the line to get it down to manageable levels.
73
Bob