To: | "Discussion of Ten-Tec Equipment" <tentec@contesting.com> |
---|---|
Subject: | Re: [TenTec] Relay for Corsair, argosy |
From: | "Ed - K9EW" <k9ew57@gmail.com> |
Reply-to: | Discussion of Ten-Tec Equipment <tentec@contesting.com> |
Date: | Thu, 18 May 2006 08:34:37 -0500 |
List-post: | <mailto:tentec@contesting.com> |
Hi Tod, Time for a trip to Radio Shack. Look for a relay with a 12vdc coil, and a contact rating of 32vdc (or higher) at 25 - 30 amp contact rating to handle the Corsair. Chances are you won't find that high a contact current rating, so do what I did - get a double-pole relay with a 15A contact rating, and connect them in parallel. I've been using that arrangement with the in-line circuit breaker for over a year now. It works fine with either rig. 73, ed - k9ew _______________________________________________ TenTec mailing list TenTec@contesting.com http://lists.contesting.com/mailman/listinfo/tentec |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [TenTec] Omni VI Plus Question, BPCI |
---|---|
Next by Date: | [TenTec] FS: 219 Filter - 250 HZ - 9 MHz IF, GARY HUBER |
Previous by Thread: | Re: [TenTec] Relay for Corsair, argosy, W8KEB |
Next by Thread: | Re: [TenTec] Relay for Corsair, argosy, James Duffer |
Indexes: | [Date] [Thread] [Top] [All Lists] |