Whoops...I didn't mean for it to come out like that! Lets try this...
Standard Standard Orion II Pre off
Orion II Pre on
S-Units uV dBm pre off
Descrep Pre on Descrep
S-5 3.16 -97
-12 dB S-6
6 dB
S-7 12.57 -85
-12 dB S-9
12 dB
S-9 50 -73 +5
5 dB +30 30 dB
+10 158 -63 +25
15 dB +42 32 dB
+20 500 -53 +40
20 dB +55 35 dB
+30 1583 -43 +52
22 dB +60 30 dB
+40 5006 -33 +62
22 dB Off Scale N/A
+50 15830 -23 Off Scale
N/A Off Scale N/A
I hope that came out on everybody's e-mail OK!
Ron
N6AHA
----- Original Message -----
From: "Ron Castro" <ronc@sonic.net>
To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
Sent: Friday, February 17, 2006 10:32 PM
Subject: Re: [TenTec] Orion (original) S-meter
> Here are the results of tests on the O2 that I made and sent to Ten Tec:
>
> S-Units
> Standard uV
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
|