Vince,

Do a battery reset to your Orion.  With power off, hold the LCK button that
is just below the "VFOB>M" button and then power on.  Continue to hold the
button until it says "Battery failure".  At this point power off.  Now you
should be able to to power on with the "RECALL" button held to start your
firmware reinstall.  Make sure the program update is not running while you
get the Orion ready for this.

Carl Moreschi N4PY
Franklinton, NC
----- Original Message ----- 
From: "Vince Santis" <vsantis@earthlink.net>
To: "Tentec" <tentec@contesting.com>
Sent: Saturday, December 24, 2005 10:13 AM
Subject: [TenTec] Orion upgrade problem


> Hi,
>
> I thought I would reinstall v 1.372 of the firmware, or an earlier
> version. However, when I attempt to do so I get an error message telling
> me of a communications failure. I only have one serial port and the
> program  defaults to Com 1. The other two options are 'Read only'
> unchecked and 'Stop on errors' unchecked.
> What am I missing?
>
> TIA,
>
> Vince Santis, N1VS
> Winsted, CT 06098
>
>
> -- 
> No virus found in this outgoing message.
> Checked by AVG Free Edition.
> Version: 7.1.362 / Virus Database: 267.14.6/213 - Release Date: 12/23/05
>
>
>


----------------------------------------------------------------------------
----


> _______________________________________________
> TenTec mailing list
> TenTec@contesting.com
> http://lists.contesting.com/mailman/listinfo/tentec
>

_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec