TenTec
[Top] [All Lists]

Re: [TenTec] Centurion

To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
Subject: Re: [TenTec] Centurion
From: "Phil Chambley, Sr." <k4dpk@comcast.net>
Reply-to: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Tue, 13 Dec 2005 22:33:57 -0500
List-post: <mailto:tentec@contesting.com>
Never tried to find new springs.

After swapping springs grid/fil, never had a problem.  Grid pins don't heat
up, so gripper doesn't lose its grip again after tightening.

Phil
----- Original Message ----- 
From: "Gary Hoffman" <ghoffman@spacetech.com>
To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
Sent: Tuesday, December 13, 2005 8:34 PM
Subject: Re: [TenTec] Centurion


> Excellent points.
>
> Can one obtain replacement gripper springs ?
>
>
>
> ----- Original Message ----- 
> From: "Phil Chambley, Sr." <k4dpk@comcast.net>
> To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
> Sent: Monday, December 12, 2005 8:19 PM
> Subject: Re: [TenTec] Centurion
>
>
> > Re 3-500Z problems....Johnson 275 and similar sockets:
> >
> > I2R losses due to poor contact between filament pins and socket grippers
> > result in melting solder out of the pins.
> > This, no doubt, caused many tubes to be discarded before it became known
> how
> > to correct the problem.
> >
> > The same heat that melts the solder causes the gripper spring to lose
its
> > temper, so the gripper doesn't squeeze the pin as tight.  If this isn't
> > corrected, the problem will simply recur.
> >
> > After repairing the tube pin, I swap the gripper springs from one of the
> > grids to the offending filament gripper on the socket.   Squeeze them
both
> > tight before installing, and make sure the grippers are all cleaned.  I
> use
> > a .22 caliber bore brush.
> >
> > 73
> > Phil K4DPK
> >
> > VFO Stabilizers and other gadgets www.k4dpk.com
> >
> >
> > ----- Original Message ----- 
> > From: "Lyle Dunlap" <lyle3dd@grics.net>
> > To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
> > Sent: Monday, December 12, 2005 11:00 AM
> > Subject: Re: [TenTec] Centurion
> >
> >
> > > Gary,
> > >
> > > Good suggestion about socket pin friction or tightness.  When the
3-400Z
> > > tube first came out, quite some time before the 500Z .  The
recommended
> > > socket at the time was made from plastic.  The fil. connections became
> > very
> > > weak and I had to use an "amp Clamp"
> > >
> > > Lyle W9FCX
> > >
> > >
> > > _______________________________________________
> > > TenTec mailing list
> > > TenTec@contesting.com
> > > http://lists.contesting.com/mailman/listinfo/tentec
> > >
> >
> >
> > _______________________________________________
> > TenTec mailing list
> > TenTec@contesting.com
> > http://lists.contesting.com/mailman/listinfo/tentec
> >
> >
>
>
> _______________________________________________
> TenTec mailing list
> TenTec@contesting.com
> http://lists.contesting.com/mailman/listinfo/tentec
>


_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec

<Prev in Thread] Current Thread [Next in Thread>