TenTec
[Top] [All Lists]

Re: [TenTec] Centurion

To: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Subject: Re: [TenTec] Centurion
From: Ken Brown <ken.d.brown@verizon.net>
Reply-to: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Fri, 09 Dec 2005 21:32:42 -1000
List-post: <mailto:tentec@contesting.com>
Hi Henry,

>Centurion Gurus -
>
No, I'm not, but I'll venture to guess anyway.

>I heard 
>a small pop - 
>
>Resting plate current at first division - about 70 ma.
>Plate voltage only 2000 volts and transformer hum sounds like the supply is 
>loaded heavily but showing only the 70 ma on the plate meter.
>
I wonder if a fault in the HV power supply rectifier or filter is 
loading the transformer, making the HV supply low as well as other 
control system and bias supplies that come from other secondaries on 
that transformer? Maybe that pop was a diode in the HV recifier going 
bad, although I understand they usually make loud pops when they do that.

I would not recommend leaving it turned on for very long while it is 
making the hum like heavily loaded.