Hello Mike and welcome to the list.

When I hear this type question, I can't help but ask my 
ex-engineering question: "How do you know your 40 Hz off?" The reason 
for the question is pretty simple, you have to have an extremely good 
calibrated frequency counter and take into account the tolerances of 
that counter and its own frequency read out.

However, if your sure you off by 40 hz on all bands, probably the 
best way to fix that is by very carefully calibrating the Omni V's 
basic crystal oscillator as precisely as you can with either 10 or 15 MHz WWV.

Regardless Mike, it is fun to tinker, isn't it?

Tommy - W4BQF


At Sunday 03:54 PM 8/14/2005, you wrote:
>Hello, Any info on alignment of freq readout for Omni V appreciated. None in
>owners manual. Readout seems to be about 40 HZ off on most bands. Thanks from
>a newcommer to the list....Mike W4ZGI