TenTec
[Top] [All Lists]

Re: [TenTec] T/R Relay on Paragon

To: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Subject: Re: [TenTec] T/R Relay on Paragon
From: Bwana Bob <wb2vuf@qsl.net>
Reply-to: wb2vuf@qsl.net,Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Sun, 20 Mar 2005 20:09:22 -0500
List-post: <mailto:tentec@contesting.com>
I just put a jumper wire from the base of the transistor that drives the 
relay to ground. Some people pop the cover off the relay and jam the 
armature down with a piece of cardboard.

                        73,

                        Bob WB2VUF

We5f@aol.com wrote:

> Hello:
> 
> I'm sure this question has been asked/answered before, but I'm new to this 
> list and could use some help.  I have a Paragon 1 with the Giehl chip, 
> version 
> 3.0.
> 
> Is there a simple way to defeat the auxiliary T/R switching relay RLY 1 on my 
> Paragon?  I will never need to switch an external amplifier, and the clicking 
> is annoying when operating CW QSK.  Could I clip the ground lead on the pot 
> to defeat the relay?  If I can't defeat it, is there a way to increase the 
> delay?  It's controlled by R33, a 100kOhm pot on the control board.  Would 
> going 
> to a 10 kOhm pot increase the delay to at least 3 seconds?
> 
> Thanks for the help!  73, Jim K5HO
> --------------
> 
> Nunquam secundum.
> _______________________________________________
> TenTec mailing list
> TenTec@contesting.com
> http://lists.contesting.com/mailman/listinfo/tentec
> 

_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec