TenTec
[Top] [All Lists]

[TenTec] #352 600 Hz Orion roofing filter kit

To: "William H. Hein" <Bill@AA6TT.com>, orion@contesting.com,tentec@contesting.com
Subject: [TenTec] #352 600 Hz Orion roofing filter kit
From: Bill Tippett <btippett@alum.mit.edu>
Reply-to: tentec@contesting.com
Date: Thu, 01 Apr 2004 09:20:36 -0500
List-post: <mailto:tentec@contesting.com>
At 04:21 PM 3/31/04, you wrote:
Bill: I am curious about the comment you made in the Ten-Tec mailing list:

"P.S.  For another $40, Inrad's #352 kit will probably buy you another ~8 dB
of IMD dynamic range at 1000 Hz spacings."

I can't find an Inrad #352 kit on their Website.  Do you mean the Inrad 752
IF filter (which is $115)?

73,
Bill NT1Y ex-AA6TT

The #352 is described here:


http://dayton.akorn.net/pipermail/orion/2004-January/000199.html

I just installed the first unit into Orion and it works great.  The
advantage is that it overcomes the intermod problems introduced
by the extra amplifier following the 500 and 250 slots.  My estimate
is that Orion's already excellent IMD for the 1000 Hz roofing filter,
 Preamp Off, will increase from ~85 dB to ~93 dB at 1000 Hz spacings.
I sold my Inrad 400 which was in the 500 slot due to the IMD problems
noted by ARRL, Sherwood Engineering and YT1NT.  I don't think Inrad
has their website updated to include this filter kit since it is brand new,
but they should be adding it here in the near future:

http://www.qth.com/inrad/exp_filt.htm

The #352 has basically the same performance curve as the #350,
but is centered on 9001.5 instead of 9000.75 allowing it to work
properly in the 1000 filter slot.

        Here are a few construction details which I need to modify
slightly since I have now completed my unit.  Bottom line is, copy
W2VJN's layout.

http://users.vnet.net/btippett/inrad_.htm

73, Bill W4ZV




_______________________________________________ TenTec mailing list TenTec@contesting.com http://lists.contesting.com/mailman/listinfo/tentec