YT1NT> At 1 kHz filter input IM level was undetectable.  The 6 kHz filter
was then inserted into 1 kHz slot

3rd order IMD products for two 700 Hz signals are both outside 1 kHz BW and
greatly influenced by skirt attenuation!

Q24 might be a bigger problem then Q9 in Orion.

73 de Mario, S56A, N1YU