With hum from two power supplies off AC line, one needs to check the electrolytic in both the TT power supply and in the 505. As I recall mine, they are cheap aluminum tubular electrolytics and with rubber ends so may have dried out. -Stuart K5KVH _______________________________________________ TenTec mailing list TenTec@contesting.com http://lists.contesting.com/mailman/listinfo/tentec |