[TenTec] It's back -- Argo V Low output

To: <tentec@contesting.com>
Subject: [TenTec] It's back -- Argo V Low output
From: ve1adh@yahoo.ca (David McClafferty)
Date: Fri Jul 25 09:49:12 2003
Have you checked to see if the correct transmit filter
has been switched in on the other bands? Also check
the receiver bandpass filters. A shorted pin diode
could cause low drive in transmit because the wrong
bandpass filter is in the circuit at all times. This
happened to my Pegasus.

73, Dave VE1ADH

 --- Rick Williams <rick.williams@telus.net> wrote: >
After my success this afternoon I had an enjoyable
> dinner and returned to
> the rig!
> 
> The problem is back.  All bands except 80 metres
> have low output. The
> voltage drop (under load) across the fuse is
> approximately 0.1 to 0.2 volts.
> I'd think that is fairly typical.
> 
> Anyway - it's back to the drawing board.
> 
> 73,
> 
> Rick
> VE7ASR
> 