Oops.
You are correct given my email. What I meant to say was the spec is +/- 3.
And reading further. that's being generous. That's supposed to be the drift
over a temperature range of 0 - 50 C. I doubt the room temp varies that
much. At room temp, I see another post that the spec is supposed to be +/- 1
ppm.
ppm.
73,
Mark
----- Original Message -----
From: "N4PY" <n4py@qvssoftware.com>
To: <tentec@contesting.com>
Sent: Wednesday, June 18, 2003 10:21 AM
Subject: Re: [TenTec] Orion TCXO Warm Up Drift
> 10 ppm at 10 mhz is 100 hertz. So it is in spec.
>
> Carl Moreschi N4PY
>
> ----- Original Message -----
> From: "Mark Erbaugh" <mark@microenh.com>
> To: <tentec@contesting.com>
> Sent: Wednesday, June 18, 2003 9:23 AM
> Subject: Re: [TenTec] Orion TCXO Warm Up Drift
>
>
> > It looks like your Orion may be out of spec. TT published specs on
> Orion's
> > temperature stability is +/- 10 ppm, At 10 MHz, that is 30 Hz. Your
Orion
> > had an excursion of 989.0 - 953.7 or 35.3 Hz. One would hope that the
+/-
> 10
> > ppm is 'worst case' but your measurements are even worse.
> >
> > 73,
> > Mark
> >
> >
> > _______________________________________________
> > TenTec mailing list
> > TenTec@contesting.com
> > http://lists.contesting.com/mailman/listinfo/tentec
>
> _______________________________________________
> TenTec mailing list
> TenTec@contesting.com
> http://lists.contesting.com/mailman/listinfo/tentec
>
>
|