thought you might like to know that the century 22 is now back in
operation
after 2 months off air !
The fault was actually a combination of two things,
1) there was a lot(i mean a lot)
of old flux on the back of,and front of the PA board.This was causing
problems around the first transisitor ,near the input.when going to transmit
it's collector went wild !
2)The PA transistors were faulty !,i had checked them with a VOM and
they
appeared ok,
also when the power was turned right down they seemed to work,anyway i
finally replaced them with
a new pair of 2sc1969's cleaned all the pa board with solvent( some sort of
alcohol,can't spell it !!) and put it all back together and hey presto it
worked.
I never dreamed that the old flux would cause such a problem.That was
the
main cause and probably caused the pa transistors to go faulty,(they
weren't open circuit !)
73's de Bill G4KKI
Member of R.I.G. RSARS.1596..FISTS 7709.