In message Thu, 3 Jul 1997 10:34:11 -0400,
  "George H. Collier" <collier@bellcore.com>  writes:


> My questions are:
>
> 1) should I get a circuit breaker (I have a fuse already)?

By all means.

> 2) Can I obtain a TenTec circuit breaker or is there a reasonable
> substitute?
>
If TT still has them and I believe they do then get one as it's less than
$20.00. This is the only way you can turn the rig off if you're using a
battery as the switch on the Corsair II is not made to handle 20A current.
The breaker is made by Air-Pax so you could buy one from them. It's a
magnetic breaker that has a much faster trip time than a fuse.

73 Jim K4CGY

--