TRLog
[Top] [All Lists]

Re: [Trlog] CI-V address for 756PROII

To: TR Log Reflector <trlog@contesting.com>
Subject: Re: [Trlog] CI-V address for 756PROII
From: Mark Bailey <kd4d@comcast.net>
Date: Tue, 12 Dec 2006 15:34:27 -0500
List-post: <mailto:trlog@contesting.com>
Hi All:

Only one post, I promise!  But, I can't resist.

To convert an ICOM address from "hex" to decimal:

first digit X 16 + second digit

For example, "56h" yields 5 x 16 + 6 = 80 + 6 = 86.

For example, "66h" yields 6 x 16 + 6 = 96 + 6 = 102.

Using a Windows calculator seems like overkill... :-)

We use the decimal system so much we "forget" that 102
is 1 x 10 x 10 + 0 x 10 + 2.  Hex works the same way,
except each position is times 16 instead of 10.

The "digits" 10-15 are represented by A, B, C, D, E,
and F, in case you see a "number" like CF.

For example, "CFh" yields 12 x 16 + 15 = 207.

73,

Mark

Mark Beckwith wrote:
> Dear Josep:
> 
> Ed said:
> 
>> TR-Log needs the ICOM address in decimal, so just convert
>> between hex and decimal to get both the radio and TR-Log
>> on the same address.
> 
> Yeah, well....for those of us to whom this is a foreign language, I have 
> included a snippet from my configuration files that helps me keep it 
> straight.  If I didn't do it this way, with the helpful comment lines, I 
> think I'd become an axe murderer.  Here's what my CFG files say, and these 
> combinations work perfectly:
> 
>               RADIO ONE TYPE = IC746PRO
>       RADIO ONE CONTROL PORT = SERIAL 2
>          RADIO ONE BAUD RATE = 4800
>   RADIO ONE RECEIVER ADDRESS = 86
> ;for base 10 "86" radio says hex "56h"
>       RADIO ONE ID CHARACTER = L
>               RADIO ONE NAME = <<<<<<<
>               RADIO TWO TYPE = IC746PRO
>       RADIO TWO CONTROL PORT = SERIAL 1
>          RADIO TWO BAUD RATE = 4800
>   RADIO TWO RECEIVER ADDRESS = 102
> ;for base 10 "102" radio says hex "66h"
>       RADIO TWO ID CHARACTER = R
>               RADIO TWO NAME = >>>>>>>
> 
> BTW you can convert from one to the other using the calculator in Windows. 
> Click on "view" and make sure "scientific" is selected, not "standard." 
> When you do, then click the bullet that says "Hex", put in the Icom address 
> you want (on the 756PROII you have a bunch of addresses to choose from in 
> the menu, right?), but don't put in the "h" - i.e. if you set the radio to 
> "66h" just put "66" onto the Windows calculator.  Then click the "Dec" 
> bullet and the amount in the display is miraculously transformed to the 
> number that you should type into TRlog.
> 
> Mark, N5OT 
> 

_______________________________________________
Trlog mailing list
Trlog@contesting.com
http://lists.contesting.com/mailman/listinfo/trlog

<Prev in Thread] Current Thread [Next in Thread>