TRLog
[Top] [All Lists]

RE: [Trlog] CAT Problems

To: "Pete" <n4kw@infionline.net>, <trlog@contesting.com>
Subject: RE: [Trlog] CAT Problems
From: "Bob Wolbert, K6XX" <k6xx@k6xx.com>
Date: Tue, 11 Nov 2003 10:21:57 -0800
List-post: <mailto:trlog@contesting.com>
And there's your problem. The FT-1000MP uses a non-standard configuration.
It is straight through, not crossed: Pin 2 goes to Pin 2, 3 to 3, and 5 to
5. And it's F to F, not the more typical "modem" M - F.

73 de Bob, K6XX
k6xx@k6xx.com

> -----Original Message-----
> From: trlog-bounces@contesting.com
> [mailto:trlog-bounces@contesting.com]On Behalf Of Pete
> Sent: Monday, November 10, 2003 9:51 PM
> To: trlog@contesting.com
> Subject: [Trlog] CAT Problems
>
>
> New PC motherboard and new FT1000 MK V.  Trying to get CAT going from
> Com 2 to XCVR.
>
> I made up a DB9 serial cable with the send/rcv reversed on one connector.
> as I have about run out.
>
> 73 Pete N4KW
>
>
>
> _______________________________________________
> Trlog mailing list
> Trlog@contesting.com
> http://lists.contesting.com/mailman/listinfo/trlog
>

_______________________________________________
Trlog mailing list
Trlog@contesting.com
http://lists.contesting.com/mailman/listinfo/trlog

<Prev in Thread] Current Thread [Next in Thread>