Hi Dick,
Firstly - try to check the PK232 (is it MBX and what's the date of EPROM
version ? DEC93 is the best) using any DOS terminal software, I suggest
Telix.
Set up communications parameters as COM2 2400,8,n,1 and check if cmd: shows
up on the screen.
If there's a garbage - the terminal speed is different or 232 is in KISS or
HOST mode.
Remove the battery jumper through the hole on the bottom, wait for a minute
or so switch 232 on back
and type a star for autospeed routine.
Set the mycall and TXD and try to connect to your DXC. if everything goes
well put the battery jumper back
and enjoy TR.
Secondly - 232 does not "like" 3-wire serial cable, use the usual modem one
25/9
Thirdly - I'm not sure if this parameter is needed -  EIGHT BIT PACKET PORT
= TRUE
Hope this helps,
73, Vic




--