David, I run / have-run TR-Log on Omni 5's / 6's / 6+'s and they all run
perfectly at 4800 baud.. You have a computer problem... Solve that and go
back to 4800 baud...
Denny
----- Original Message -----
From: "David H. Walker" <k0cop@earthlink.net>
To: <trlog@contesting.com>
Sent: Thursday, November 30, 2000 6:29 AM
Subject: [TRLog] TENTEC Behavior
>
> I would like to thank everyone for the reply to Strange Behavior from my
> Omni Six Plus. I now have TR Log set for 1200 Baud and the radio adjusted
> to 1200 Baud. Also the CdE is set to OFF in the TenTec. I think that the
> Baud issue was the fault. All FB thanks to the very kind replies.
> Best to all
> 73
> David
>
> David H. Walker
> Pawleys Island,SC 29585
> k0cop@earthlink.
> K0COP
> FISTS# 4748
> QCWA
>
>
> --
> FAQ on WWW: http://www.contesting.com/FAQ/trlog
> Submissions: trlog@contesting.com
> Administrative requests: trlog-REQUEST@contesting.com
> Problems: owner-trlog@contesting.com
> Feature Wishlist: http://web.jzap.com/n6tr/trwish.html
>
--
FAQ on WWW: http://www.contesting.com/FAQ/trlog
Submissions: trlog@contesting.com
Administrative requests: trlog-REQUEST@contesting.com
Problems: owner-trlog@contesting.com
Feature Wishlist: http://web.jzap.com/n6tr/trwish.html
|