At 11:42 AM 10/31/98 +0000, Ted Sarah wrote:
>
>With 6.32 I was able to get the CTL-B to work and bring up the packet
>window.  But, what came across was gibberish and was unable to type
>anythng.  I tried all the various options dealing with packet, but no
>luck.  I'm using a laptop running Windows 95 and the TNC is a
>MFJ-1270C.  Any ideas?
>
>73 - Ted - W8TTS

Ted

I'm not familiar with the MFJ units but it sounds like you need to reset
the baud rate of the TNC's interface to the PC, to match the baud rate
being specified by TRLog. In both cases you should  be using 4800 baud for
the serial interface. 

Dave 