My system is still taking from 15 seconds to 1 minute to see changes
to the frequency. I do have CTS-RTS jumpered. I don't have DSR-Carrier
detect since neither pins 1 nor 6 in the Kenwood have any connection.
They are Carrier Detect and DSR and I guess kenwood has no use for
them.

The real problem is that the jumper information in the manual is not
consistent. It says for DB25 to use 6 to 8  (DSR-CD) and 4 to 5
(RTS-CTS). I think this is correct. The information for the DB9 which
I use says 1 to 6 (DSR-CD) which is the same function as the DB25 BUT
it says 4 to 7 (DTR-RTS) which is not at all the same thing. I think
it should be 7 to 8 (RTS-CTS) as on the DB25. This has caused me a LOT
of time and trouble. I hope I can avoid that for someone else. 
Even with this setup, it still takes a long time to see changes and I
don't think that should happen but I don't think it will ever miss it
when you actually make a log entry so I will live with it.
-- 
Gil Baron W0MN gbaron@sparc.isl.net 
http://www.geocities.com/Yosemite/Trails/4168/
Bailar es vivir" pgp2.6 key http://www-swiss.ai.mit.edu/~bal/pks-toplev.html
"Cuatro caminos hay en mi vida. Cual de los cuatro sera el mejor" 
[Posted with Agent 1.5. For info, email agent-info@forteinc.com.]

--
FAQ on WWW:               http://www.contesting.com/trlogfaq.html
Submissions:              trlog@contesting.com
Administrative requests:  trlog-REQUEST@contesting.com
Problems:                 owner-trlog@contesting.com
Feature Wishlist:         http://web.jzap.com/n6tr/trwish.html

<Prev in Thread] Current Thread [Next in Thread>
  • [TRLog] Serial cable wiring, Gilbert Baron <=