The HF-2500 is extremely sensitive to grid current. 5 or so years ago, we used
one in an SSB contest at KC1XX and the thing shut down on a frequent basis.
NEVER AGAIN. We have at least 4 (maybe more) AL-1200s at Matt's place now and
we never have to think about them - they're RUGGED. But I agree, I wouldn't
run one for 48 hours at full power near 100% duty cycle!
73 - Jim AD1C
--- Shelby Summerville <k4ww@home.com> wrote:
> As a "happy without any problem" owner of an AL-1200, I take exception to
> your opinion, to which you are entitled! I have seen a HF-2500 exhibit the
> same problem, unless the drive power was reduced!
=====
Jim Reisert AD1C, 7 Charlemont Court, North Chelmsford, MA 01863
USA +978-251-9933, <jjreisert@alum.mit.edu>, http://www.ad1c.com
__________________________________________________