RFI at 2M is a good candidate for #43 or #31 clamp-ons without a second turn on wiring connected to the source. You may need more than one. Multiple turns through #31 will be required for suppression at HF.

73, Jim K9YC

On 11/17/2021 6:05 AM, nlsa@nlsa.com wrote:
Dear friends,
I am seeing RFI on 2m from the cathodic protection circuit in our geothermal
heating system.  The protective circuit's on-board SMPS generates a large
broad emission around 150 MHz, verified with a spectrum analyzer and
sniffer.  Before I dive in with the usual filters and toroids, does anyone
on the list have experience and suggestions?
Thank you,
Michael Owen