On 11/15/2021 5:43 AM, kq3f@comcast.net wrote:
I suspect the noise is coming from the transformers. Any idea how to deal
with this, or do I need to replace the lights with something else? Thanks in
advance for any hel

I suspect that there are no TRANSFORMERS (2-windings, magnetically coupled on a iron core) in this system. Rather, what they are CALLING transformers are switch-mode power supplies (SMPS), that convert 120VAC to low voltage DC to power the LEDs.

SMPSs are notorious noise generators. I found them in back-cans for lighting in the bathroom of the home we bought in CA, generating bodacious noise. When I went to local electrical supply looking for a transformer, they tried to sell me another SMPS that they called a "transformer."

73, Jim K9YC