RFI
[Top] [All Lists]

Re: [RFI] Icom PS-125

To: Leonard Halvorsen <lhalvors@pppl.gov>
Subject: Re: [RFI] Icom PS-125
From: "Dale J." <dj2001x@comcast.net>
Date: Fri, 19 Sep 2014 16:25:41 -0500
List-post: <rfi@contesting.com">mailto:rfi@contesting.com>
I have one, used it for some amount of time and was RFI quiet, it worked well 
while it worked.  It's dead now, but I'm not going to spend time or money 
fixing it.  It is relegated to under a shelf, on the concrete floor in my 
basement shop.  Perhaps there's an easy fix, but switching PS's are not too 
easy to troubleshoot and fix, at least for me.  

73
Dale, K9VUJ


  
On 19, Sep 2014, at 15:43, Leonard Halvorsen <lhalvors@pppl.gov> wrote:

> *Anyone out there using an ICOM PS-125 Power Supply?*
> 
> *I have TWO. **They were bought within about 2 or 3 weeks of each other. I
> was very pleased with them when they were new, but they don't seem to be
> aging well. Both were dead-quiet, even on 160M. Lately, the noise level
> seems to be creeping up on them, one on 80M, the other on 160 & 80M.
> They're only a few years old. I know component values change with age, but
> I didn't think it would happen so quickly.*
> 
> *Anyone else having the same trouble?*
> 
> *Leo*
> *WA2AMW*
> _______________________________________________
> RFI mailing list
> RFI@contesting.com
> http://lists.contesting.com/mailman/listinfo/rfi

_______________________________________________
RFI mailing list
RFI@contesting.com
http://lists.contesting.com/mailman/listinfo/rfi