Wes,
You are right and I should have already done that. I will try it next time
the XYL lets me shut down the internet.
73, Dan
-----Original Message-----
From: Wes Attaway (N5WA)
Sent: Tuesday, March 26, 2013 11:43 AM
To: 'Dan Butler' ; rfi@contesting.com
Subject: RE: [RFI] 30 M Shuts Down Internet Cable Modem
You could just cut the wires on the wall warts and wire the correct plug
onto a different wall wart. You don't even need to solder the connections
...just twist the wires for a test. You aren't risking much.
----------------- Wes Attaway (N5WA) -------------------
1138 Waters Edge Circle, Shreveport, LA 71106
318-797-4972 (Office) - 318-393-3289 (Cell)
Computer Consulting and Forensics
-------------- EnCase Certified Examiner ---------------
-----Original Message-----
From: Dan Butler [mailto:ttexan@hotmail.com]
Sent: Monday, March 25, 2013 10:33 PM
To: Wes Attaway (N5WA); rfi@contesting.com
Subject: Re: [RFI] 30 M Shuts Down Internet Cable Modem
Thanks Wes. I have ordered both the 1:1 balun and several type 43 rings
from Palomar in the US and hopefully they will arrive in the next couple of
weeks.
Unfortunately, out of all the connections and wall warts I have in my junk
box, I do not have anything that will fit the jack on this modem. I can
check with some of the local suppliers here in Singapore but it is a bit
like looking for a needle in a haystack. However, if the ferrite rings are
not successful, that will be my next move. The internet provider supplies
the modem and I really do not want to approach them on the issue as I am one
of only 10 active hams in Singapore and once they know about me, I will
probably be the "cause" of any issues in my area.
73, Dan
-----Original Message-----
From: Wes Attaway (N5WA)
Sent: Tuesday, March 26, 2013 11:21 AM
To: 'Dan Butler' ; rfi@contesting.com
Subject: RE: [RFI] 30 M Shuts Down Internet Cable Modem
One thing to look at would be the power cube that feeds the modem. There
are a couple of things to try. One would be to wrap as many turns of the IN
and OUT wires around toroid cores. Jim Brown would probably give good
advice on this. Try whatever cores you have, although Type 31 might be the
best if you have it.
Alternatively, you could try a different power supply to feed the proper
voltage to the modem.
I helped a local ham recently who had bad TVI on several TV sets (DirecTV)
and we narrowed the problems down to the power units feeding the DirecTV
boxes. He replaced the power supplies with units from Radio Shack and the
TVI went away.
----------------- Wes Attaway (N5WA) -------------------
1138 Waters Edge Circle, Shreveport, LA 71106
318-797-4972 (Office) - 318-393-3289 (Cell)
Computer Consulting and Forensics
-------------- EnCase Certified Examiner ---------------
-----Original Message-----
From: RFI [mailto:rfi-bounces@contesting.com] On Behalf Of Dan Butler
Sent: Monday, March 25, 2013 9:44 PM
To: rfi@contesting.com
Subject: [RFI] 30 M Shuts Down Internet Cable Modem
I live on the 15th floor of a 17 story apartment so "proper" grounding is
not possible. I use an end fed multiband dipole which theoretically does not
require RF grounding. However, I do have a multiple wire counterpoise hooked
to the tuner. I recently converted from a 20/40 end fed dipole to the 6-80
end fed dipole, so have just started using the other bands. Now when I TX on
30 M (and occasionally 17 M) the internet cable modem which is in an
adjacent room about 20 feet away, cuts off - all the lights go out, then it
starts once the TX is finished. I placed a steel bowl over it and wrapped it
in foil but it still cuts off. I disconnected the router cable and the cable
input and it still cuts off. I presume I have some sort of power supply
issue but not sure how to address that.
Thanks in advance for any useful suggestions.
73, Dan 9V1DB
_______________________________________________
RFI mailing list
RFI@contesting.com
http://lists.contesting.com/mailman/listinfo/rfi
_______________________________________________
RFI mailing list
RFI@contesting.com
http://lists.contesting.com/mailman/listinfo/rfi
|