Lee,
This is possible. I have some transmission lines (don't know what
voltage they are) and a substation a little less than a mile away. I
just need to wait for conditions to get wet again, then I'm going to do
the breaker-off test at the house and go for a drive with the 706 to see
if I can narrow down the source.
Thanks for all of the suggestions!
Matt, N0EYE
On 3/15/2013 10:44 PM, Lee K7TJR wrote:
Matt, If you live within a mile or two of any 100 to 500 KV power
lines you may be getting corona noise. At my previous QTH I could
count on the high pitched buzz any time it rained or snowed or even in
super heavy fog. I had both a 1/2 mile away 100KV and a mile away 380
KV and they both just howled when wet.
Lee K7TJR OR
*From:* Matt <mailto:wedgef5@gmail.com>
I'm having a problem with very strong, very broad noise that seems to be